Cardiology Casebook of IVUS/OCT with Videos

Six-Month Follow-Up of In-Stent Restenosis Treated with Drug-Coated Balloon Using Optical Coherence Tomography

Researchers & Contributors

Manish Kumar Sharma

Senior Consultant

Department of Cardiology

Sir Ganga Ram Hospital

New Delhi

Arun Mohanty

Senior Consultant

Department of Cardiology

Sir Ganga Ram Hospital

New Delhi

Manikanth Vivek

DNB Resident

Department of Cardiology

Sir Ganga Ram Hospital

New Delhi

Ashish Kumar Jain

Associate Consultant

Department of Cardiology

Sir Ganga Ram Hospital

New Delhi

Case Videos

Video 1A

Coronary angiography showing mid 90–95% in-stent restenosis of the left anterior descending artery – Run A.

Video 1B

Coronary angiography showing mid 90–95% in-stent restenosis of the left anterior descending artery – Run B.

Video 2A

CAG: Mid-LAD 90–95% ISR and 30–40% plaquing in mid-RCA – Run A.

Video 2B

CAG: Mid-LAD 90–95% ISR and 30–40% plaquing in mid-RCA – Run B.

Video 3A

Predilation of lesion using a Pipit NC 2.5 × 15 mm balloon at 12–14 atm for 15 seconds – Run A.

Video 3B

Predilation of lesion using a Pipit NC 2.5 × 15 mm balloon at 12–14 atm for 15 seconds – Run B.

Video 4

LAD follow-up PCI OCT-run: mild stent underexpansion, calcified neoatherosclerosis, MLA ~0.74 mm².

Video 5A

Plaque modification with Wolverine cutting balloon 3 × 10 mm at 12–14 atm for 15 seconds – Run A.

Video 5B

Plaque modification with Wolverine cutting balloon 3 × 10 mm at 12–14 atm for 15 seconds – Run B.

Video 6A

Dilatation using Sapphire NC 3.5 mm balloon at 14 atm for 15 seconds – Run A.

Video 6B

Dilatation using Sapphire NC 3.5 mm balloon at 14 atm for 15 seconds – Run B.

Video 7

Post cutting & NC LAD follow-up PCI OCT-run showing improved MLA of ~5.2–7.1 mm².

Video 8A

Paclitaxel drug-coated balloon (Agent 3.5 × 30 mm) deployment at 8 atm for 60 seconds – Run A.

Video 8B

Paclitaxel drug-coated balloon (Agent 3.5 × 30 mm) deployment at 8 atm for 60 seconds – Run B.

Video 9

Post-DEB LAD follow-up PCI OCT-run: adequate previous stent expansion, no edge dissection, improved MLA.

Video 10

Final angiogram showing good result with TIMI-III flow.

Video 11

CAG performed after 6 months.

Video 12

6-month post-DCB LAD follow-up OCT-run: neointimal hyperplasia, no edge dissection, adequate MLA.